Installation

The machine must be installed on a flat and stable surface.

The machine must be connected to compliant electrical and pneumatic outlets.

Using damaged equipment can be dangerous for the user and the machine. If you have received damaged equipment, contact the manufacturer.

A safety clearance of 0.5 m around the machine is required.

Do not install the machine near a radiator or a window.

Heavy product, handle with care.

The machine is equipped with optical sensors and therefore requires sufficient light to operate.

Install the machine in a frost-free location (4°C to 5°C minimum).

Electrical Connection

The electrical installation must include an all-pole disconnection device (fuse holders, circuit breaker), in accordance with local installation regulations in force.

It is recommended to use the cables provided with the machine.

Earthing is mandatory.

Maintenance

Maintenance operations are reserved for qualified personnel only.

Unplug the machine before performing any maintenance operation.

The manufacturer Ravoux Automatismes

located at Rue de l'Industrie, 03300 Creuzier-Le-Vieux, France

declares under its sole responsibility that the machine MINIDOSA - Perfume packaging system

(serial number: MINIDOSA-1992-72685), manufactured in 1992,

is in conformity with the provisions of:

Regulation (EU) 2023/1230 of the European Parliament and of the Council of 14 June 2023 on machinery,

repealing Directive 2006/42/EC.

Applied harmonised standards:

EN ISO 12100:2010 – Safety of machinery – General principles for design,

EN 60204-1:2018 – Safety of machinery – Electrical equipment of machines,

NF X 60-200 - Nomenclature and general drafting principles,

FD X 60-212 - Maintenance instructions framework,

NF X 60-210 - Rules for presentation and drafting of spare parts catalogues.

Name: Émilien PAPIN

Place: Limoges

Date: 13/03/2026

Illustration ce

Documentation Overview

This documentation is divided into two volumes. Its purpose is to document the installation, operation, and maintenance procedures for the MINIDOSA perfume packaging system.

Illustration carte-doc-main-1

First volume: MINIDOSA - 1. User Manual

The first volume is dedicated to operations performed by users. It describes the stages of commissioning, adjustment, operation, and shutdown of the machine, as well as essential safety instructions.

Second volume: MINIDOSA - 2. Maintenance Manual, Spare Parts Catalogue and Appendices

The second volume is dedicated to the installation of the MINIDOSA machine, advanced technical interventions, and the identification of spare parts. The objective is to provide clear, structured, and directly applicable documentation to ensure:

- compliant installation of the system;

- conformity of packaging operations;

- user safety;

- preservation of equipment integrity.

Illustration carte-doc-main-1a

The machine description is available in the first volume of the documentation: "MINIDOSA: 1. User Manual".

Illustration carte-doc-util-1a

icon
The surface intended to accommodate the machine must be level and stable. The use of an inclinometer is recommended. The surface must be able to support 110 kg.
Position the machine.
Secure the machine to its support.
Illustration en-install-espace

icon
A 230 V earthed male electrical socket and a 6-bar compressed air supply are required.
icon
Use the cables provided with the machine. They must be in good condition. The provided power cable is 1.5 m long.
Connect the power cable to the electrical socket.
Connect the supply hose to the compressed air outlet.
Illustration raccorder-machine-1

icon
The machine must be electrically and pneumatically connected.
icon
The air valve must be open (for more information, consult the first volume of this documentation: "MINIDOSA: 1. User Manual - Chapter 5.1. Supplying the machine with air and electricity").
Pull the pressure regulator knob to unlock it.
Turn the knob to adjust the pressure between 4 and 6 bars.
Push the pressure regulator knob to lock it.
Illustration regler-pression

icon
Level 2 maintenance is reserved for qualified personnel only.

Close the valve located under the tank.
Unscrew the nut connecting the tank to the hose.
Place a container under the tank.
Open the valve under the tank.
Illustration en-reservoir1

icon
The electrical and pneumatic supplies must be switched off.
Unscrew the eight screws holding the ramp.
Remove the old supply track.
Position the supply track by aligning the holes intended to accommodate the screws.
Rescrew the eight screws.

icon
Level 3 maintenance is reserved for qualified personnel only and requires specific tools.

icon
The electrical and pneumatic supplies must be switched off.
icon
If the cylinder has failed prematurely, check: pressure, mechanical stop, alignment.
Loosen the hose clamp holding the pneumatic fitting on the cylinder.
Disconnect the pneumatic fitting from the cylinder.
Unscrew the ten screws of the cylinder.
Remove the cylinder.
Install the cylinder by aligning the pivoting arm.
Rescrew the ten screws of the cylinder.
Reconnect the pneumatic fitting to the cylinder.
Retighten the pneumatic fitting hose clamp.
Test the cylinder by performing a single unit production.
icon
For more information, consult the first volume of this documentation: "MINIDOSA: 1. User Manual - 6.2. Packaging perfume bottles individually".
Check the proper drive of the indexing table.
Illustration en-verin-plateau

icon
The electrical and pneumatic supplies must be switched off.
icon
Use an appropriate replacement motor 7. - Spare Parts Catalogue
Detach the power cable retaining clip.
Disconnect the power cable from the motor.
Unscrew the four motor screws.
Remove the old motor.
Position the new motor by aligning the holes intended to accommodate the screws.
Rescrew the four motor screws.
Reconnect the power cable to the motor.
Attach the power cable retaining clip.
Test the motor by performing a single unit production.
icon
For more information, consult the first volume of this documentation: "MINIDOSA: 1. User Manual - 6.2. Packaging perfume bottles individually".
Measure the vibration rate and sound pressure.
Illustration moteur1

Overview Name Reference Supplier
moteur-1
Motor, 250 V AC - 50Hz - 45W AZ-6592 SNT
moteur-1
Motor, 24 V DC - 45W NX-0606 BOSCH

Overview Name Reference Supplier
verin-1
Double-acting pneumatic cylinder, 10A F65-8214 RAVOUX
verin-1
Double-acting pneumatic cylinder, 11A F85-8658 RAVOUX
verin-1
Triple-acting pneumatic cylinder, 12A T800-C137 RAVOUX

Overview Name Reference Supplier
capteur-1
Detection arch, 24V DC - 10W F95-4050 RAVOUX
capteur-2
Inductive sensor, 24V DC - 10W ZE-2023 RAVOUX
capteur-3
Optical sensor, 24V DC - 10W UI72-7898 RAVOUX

Overview Name Reference Supplier
ampoule-1
Incandescent bulb, 24V DC - 2W AB-1870 MOTION TWIN
cache-1
Plastic cover for indicator light IO-3000 MOTION TWIN

Overview Name Reference Supplier
flacon-1
Bottle FN-300 E.P. Works
bouchon-1
Cap BN-301 E.P. Works
liquide-2
Cleaning Liquid LN-302 E. P. Works
liquide-1
Perfume Liquid "Geranium's Ultimate Winter" PUB-3001 E. P. Works
liquide-3
Perfume Liquid "Winds from the Dunes" PUB-3003 E. P. Works
liquide-5
Perfume Liquid "DeLorean's Quantum Essence" PUB-3005 E. P. Works